System
Errors and T
raf
fic Pegs 8-27
Octel Overture 200/300 Serenade 3.0
PB60014–01
Table 8-2
Hardware Error T
ypes and Remedies (continued)
Error T
ype:Name PriorityRemedySource
43. Hard
Disk/
Language T
able
Read/W
rite Err
or
Error detected in the
read/write of language
table
Errors 1 or 3 — Run FLOPPY Backup/
Restore.
Errors 2, 5, 6, 7, or 8 — Run Disk
Exerciser command.
3
DATA-1 = ERROR CODE, AS FOLLOWS:
01 = NO LANGUAGE LOADED
02 = NO ACTIVE SYSTEM DISKS FOR READ
03 = CK SUM ERROR ON READ
04 = TABLE SIZE ERR
05 = CAN’T READ EITHER SYS-DISK
06 = ERR ON WRITE TO DISK #1
07 = ERR ON WRITE TO DISK #2
08 = ERR ON WRITE TO BOTH DISKS
09 = LANGUAGE QTY LOADED EXCEEDS OCC MAX
44. CPU/VCU
Request/Reply
Checksum
Err
or
A protocol error
occurred between the
CPU and VCU on the
control bus.
Contact your technical support center
. 3
DATA-1 = NUMBER OF RETRIES ATTEMPTED BEFORE TRANSACTION
SUCCEEDED OR ABANDONED (MAXIMUM OF 3).
DATA-2,
DATA-3,
DATA-4 = FAILURE REASON FOR EACH ATTEMPT:
01 = NO ERROR (RETRY SUCCEEDED)
02 = CONTROL BUS TIMEOUT ATTEMPTING TO READ
CPU CB STATUS REGISTER
03 = CONTROL BUS TIMEOUT ATTEMPTING TO READ
VCU SHARED RAM
04 = CONTROL BUS TIMEOUT ATTEMPTING TO WRITE
VCU SHARED RAM
05 = INCORRECT CHECKSUM ON VCU REPLY BUFFER
06 = VCU DETECTED CHECKSUM ERROR ON CPU
REQUEST BUFFER
45. VCU
Reply
Language Set
Error
The VCU has replied
that there is an error in
a language set.
Contact your technical support center
. 3
DATA-1 = THIS ERROR NUMBER
DATA-2 — BIT MAP HI BITS= LOAD FAULT
DATA-3 — BIT MAP HI BITS= NOT LOADED