Page view 269
6-40
Installation and Maintenance
Volume
Octel Overture 200/300 Serenade 3.0
PB60014–01
If
only one port is specified, the Octel Overture 200/300 tries to initialize and cancel forwarding for only
the port specified. If a range is specified, the message server tries to initialize and cancel forwarding for
all ports in the range. If no port is specified, the message server tries to initialize and cancel forwarding
for all ports. If a port is successfully initialized and forwarding is canceled, it goes to the IDL state. If a
port fails to complete either the initialization or the forwarding, the status remains NDT
.
For additional information about using the
CU x y z
command, refer to the System Service Mode
Commands, Courtesy Up/Courtesy Down, section.
System
Status
Use
the
TEST STATUS
command to check the message server status for d.c. voltages and the
temperature. At the @ prompt, type
TE S

If
d.c. voltages and the temperature are within acceptable ranges, the Octel Overture 200/300 responds
with the following:
SYSTEM STATUS TESTED OK.
If
d.c. voltages and the temperature are out of range, the Octel Overture 200/300 responds with the
following:
ERROR DETECTED. SEE HARDWARE ERROR TABLE.
List
Features
Use
the
LIST FEATURES
command to list the following:
Optional feature packages installed
Number of installed, authorized, and used ports, mailboxes, and disk-storage hours
Maximum number of drives, ports, and languages allowed in the message server
At the @ prompt, type
L F

Page view 269