Reliant FVIR GAS WATER HEATER Technical Information Page 46

  • Download
  • Add to my manuals
  • Print
  • Page
    / 75
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 45
RESIDENTIAL GAS AND ELECTRIC WATER HEATER
TROUBLESHOOTING and SERVICE HANDBOOK
RELIANCE Water Heater Company Technical Training Department
©2006 Ashland City, TN
46
Residential Electric – continued
A-6 service – continued
Testing with the Multimeter
Probes installed to test for "voltage - (black test lead is “common".)
Dial set to AC - Voltage scale - set dial to highest voltage scale or scale above the
expected voltage. Do not set the meter to a scale below the voltage expected.
Complaint: No hot water
Test Conditions:
Tank is full of cold water.
Power is "on" to the heater
Voltage Check
Test between 1 and 3 or L1 and L3
If … … then
correct supply voltage is present continue.
correct supply voltage is NOT present
check disconnect breaker.
check wiring to the heater.
Test between 2 and 4 or L1 and L4
If … … then
correct supply voltage is present continue
correct supply voltage is NOT present,
push Manual Reset - if power is now supplied,
conduct thermostat and element checks.
still no power replace High Limit (High Limit/Thermostat on
89T)
Page view 45
1 2 ... 41 42 43 44 45 46 47 48 49 50 51 ... 74 75

Comments to this Manuals

No comments